Focused fluid flow and the sub-seabed storage of CO2 : Evaluating the leakage potential of seismic chimney structures for the Sleipner CO2 storage operation.

Karstens, Jens , Ahmed, Waqas, Berndt, Christian and Class, Holger (2017) Focused fluid flow and the sub-seabed storage of CO2 : Evaluating the leakage potential of seismic chimney structures for the Sleipner CO2 storage operation. Marine and Petroleum Geology, 88 . pp. 81-93. DOI 10.1016/j.marpetgeo.2017.08.003.

[thumbnail of Karstens.pdf] Text
Karstens.pdf - Published Version
Restricted to Registered users only

Download (4MB) | Contact

Supplementary data:

Abstract

Highlights

• Seismic chimneys represent potential leakage pathways for CCS sites.
• Simulations indicate that CO2 will not reach chimney structures at Sleipner.
• Detailed palaeo fluid system reconstruction is crucial for CCS site selection.

The integrity of the caprock of a storage formation is the most crucial parameter for the long-term performance of a geological CO2 storage site. The Sleipner area in the Southern Viking Graben hosts the first and longest operating industrial scale CO2 storage project, where CO2 is injected in a saline aquifer of the Utsira Formation. Time-lapse seismic monitoring shows neither that CO2 has left the Utsira Formation nor indications for fracturing of the caprock by the CO2 injection activity, which is in agreement with previous numerical simulations. However, large chimney structures as close as 7 km from the injection point indicate that the caprock has been breached in the geological past, which may raise questions about the integrity of the caprock above the Sleipner CO2 storage site. Here, we present seismically constrained numerical fluid flow simulations that evaluate the influence of chimney structures on the long-term performance of the CO2 storage operation at Sleipner. The simulation could reproduce the spreading of the Sleipner CO2 plume, which is controlled by the anisotropic permeability field of the Utsira Formation and the regional dip of the formation top. We have performed long-term plume evolution simulations, which show that the injected CO2 will not reach the existing chimney structures assuming a realistic injection duration of 30 years. Our simulations indicate that an unrealistically long injection period between 92 and 140 years would be required for the CO2 to reach the existing chimney structures. In this case, a comparably low chimney permeability of 10 mD may be sufficient to facilitate CO2 migration from the storage formation to the seafloor, once the CO2 has reached a chimney structure. However, the simulations indicate that it is very unlikely that the CO2 may migrate along existing chimney structures at Sleipner. Our results highlight that the reconstruction of palaeo fluid flow systems and the identification of focused fluid conduits should be considered in the assessment of CO2 storage sites.

Document Type: Article
Funder compliance: info:eu-repo/grantAgreement/EC/FP7/265847
Keywords: CCS ; Fluid flow simulation ; Leakage potential ; Seismic chimney ; Sleipner
Research affiliation: OceanRep > GEOMAR > FB4 Dynamics of the Ocean Floor > FB4-GDY Marine Geodynamics
Kiel University
Refereed: Yes
Open Access Journal?: No
Publisher: Elsevier
Projects: ECO2
Date Deposited: 07 Sep 2017 09:26
Last Modified: 06 Feb 2020 09:08