Near quantitative separation of analyte elements from the sample matrix is commonly required to obtain precise and accurate stable isotope data, especially if MC-ICP-MS is used in conjunction with the standard-sample bracketing (SSB) technique for mass bias drift correction. Here, we report a robust procedure that allows for the combined chemical separation of Mg, Ca and Fe, using ion-exchange columns that contain 1 ml AG50W-X8 (200-400 mesh) cation exchange resin. Magnesium was separated for isotope ratio analyses from many geological sample types by a single pass through this column. For Mg purification, Be, Ti, Mn, Fe and Al are selectively eluted using dilute HF and an acetone-HCl mixture. The separation of Mg from Ca-dominated carbonate samples and/or a combination of Mg, Ca and Fe separation from the same sample aliquot, is achieved by the adsorption of Ca and Fe onto the ion-exchange resin from 10 M HCl. Following purification, geological reference materials, including water, bone, carbonate and sediment samples, igneous and sedimentary rocks and a chondritic meteorite were analysed by MC-ICP-MS (Mg and Fe isotopes) and double-spike TIMS (Ca isotopes). Average external repeatabilities were +/-0.16 parts per thousand for Mg-26/Mg-24, +/-0.26 parts per thousand for Ca-44/Ca-40 and +/-0.05 parts per thousand for Fe-56/Fe-54 (2sd; n >= 5). Comparison with published data documents the accuracy of the results. For Mg isotope analyses using SSB-MC-ICP-MS, matrix-induced mass bias effects were studied using element additions. The artificial matrices left a memory in subsequent standard analyses, likely due to depositions on the cones. This observation allowed for the detection of matrix effects in unknown samples. Finally, the current status of Mg and Ca zero-delta reference materials is briefly discussed.

Document Type: Article
Keywords: Geology, Inductively coupled plasma/MS, Isotope analysis, Sample handling, Sample preparation, Mg, Ca, Fe
Research affiliation: OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-MG Marine Geosystems
OceanRep > The Future Ocean - Cluster of Excellence
Refereed: Yes
Open Access Journal?: No
DOI etc.: 10.1039/b820154d
ISSN: 0267-9477
Projects: Future Ocean
Date Deposited: 04 Dec 2009 12:26
Last Modified: 09 Jun 2017 12:07
URI: http://oceanrep.geomar.de/id/eprint/7287

Actions (login required)

View Item View Item

Document Downloads

More statistics for this item...