Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode.

Hassan, Khalid Mahmoud, Gaber, Seleem Elsaid, Altahan, Mahmoud F. and Azzem, Magdi Abdel (2020) Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode. Open Access Sensing and Bio-Sensing Research, 29 . Art.Nr. 100369. DOI 10.1016/j.sbsr.2020.100369.

[thumbnail of 1-s2.0-S2214180420300908-main.pdf]
Preview
Text
1-s2.0-S2214180420300908-main.pdf - Published Version
Available under License Creative Commons: Attribution-Noncommercial-No Derivative Works 4.0.

Download (3MB) | Preview

Supplementary data:

Abstract

In this work, bimetallic film of mercury and bismuth (Hg-Bi) was incorporated with poly(1,2-diaminoanthraquinone)/glassy carbon electrode (PDAAQ/GC) using applied potential method. The obtained Hg-Bi/PDAAQ/GC electrode was characterized by square wave voltammetry (SWV), scanning electron microscope (SEM) and energy dispersive X-ray (EDX) techniques. The proposed electrode had been used as a highly sensitive sensor for both single and simultaneous determination of lead (Pb2+), cadmium (Cd2+) and zinc (Zn2+) ions in acetate buffer solution by anodic stripping voltammetry (ASV). The adopted ASV method was achieved by optimizing different parameters such as metal deposition method (either in-situ or ex-situ), metals pre-concentration potential, pre-concentration time and different pH of values for acetate buffer solution. The prepared sensor provided a good reproducible response, high sensitivity with a linear range of 0.0–50.0 μg/L for Cd2+ and Zn2+ with a low detection limit of 0.107 and 0.037 μg/L, respectively. The linear range of Pb2+ was 10.0–120.0 ng/L with a detection limit of 3.18 ng/L. Also, the sensor was used for the analysis of the analytes in water samples with satisfactory results in comparison with inductively coupled plasma – mass spectroscopy (ICP-MS).

Document Type: Article
Keywords: Poly (1,2-diaminoanthraquinone) modified electrode Αnodic stripping voltammetry; Βimetallic Hg-Bi; Ηeavy metal ions
Research affiliation: OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-CH Chemical Oceanography
Refereed: Yes
Open Access Journal?: Yes
Publisher: Elsevier
Date Deposited: 17 Aug 2020 12:44
Last Modified: 08 Feb 2023 09:28
URI: https://oceanrep.geomar.de/id/eprint/50338

Actions (login required)

View Item View Item