Plasma Protein Binding of Luciferase Substrates Influences Sensitivity and Accuracy of Bioluminescence Imaging.
Keyaerts, M., Heneweer, C., Gainkam, L. O. T., Caveliers, V., Beattie, B. J., Martens, G. A., Vanhove, C., Bossuyt, A., Blasberg, R. G. and Lahoutte, T. (2011) Plasma Protein Binding of Luciferase Substrates Influences Sensitivity and Accuracy of Bioluminescence Imaging. Molecular Imaging and Biology, 13 (1). pp. 59-66. DOI 10.1007/s11307-010-0325-x.
Full text not available from this repository.Abstract
Potential confounding factors in bioluminescence imaging (BLI)-quantification need to be identified to improve its accuracy and repeatability. The aim of this study was to study the degree to which plasma protein binding of BLI substrates influences signal intensity and quantification, both in vitro and in vivo. Protein binding was assessed using ultrafiltration and spectrophotometry. Effects of increasing serum protein concentrations were studied in vitro, in intact cells expressing Firefly or Renilla luciferase, and in vivo, in a doxorubicin-induced hypoalbuminemia mouse model. Increasing concentrations of serum proteins showed an important negative effect on BLI signal intensity, both for d-luciferin and coelenterazine-dependent reactions. This was due to a decrease in the free fraction of the substrate in the presence of serum proteins of up to 88. In vivo, hypoalbuminemia was associated with higher BLI signal intensity, although this was only significant in animals with a major decrease in albumin (< 2 g/dL). Important kinetic differences, including earlier peak luminescence and a more rapid decline in luminescence, were observed for coelenterazine-dependent BLI under hypoalbuminemic conditions. Changes in protein concentrations can significantly influence BLI quantification and its presence decreases sensitivity in vitro. In vivo, effects on signal intensity and kinetics are only noted at severe hypoalbuminemia and can be neglected in most experimental designs. These findings again emphasize the need for careful interpretation of BLI quantification data.
Document Type: | Article |
---|---|
Keywords: | Bioluminescence imaging Protein binding Small animal imaging Molecular imaging Tumor model disease progression gene-expression reporter kinetics growth models impact assays |
Refereed: | Yes |
Date Deposited: | 01 Nov 2012 05:06 |
Last Modified: | 01 Nov 2012 05:06 |
URI: | https://oceanrep.geomar.de/id/eprint/17718 |
Actions (login required)
View Item |
Copyright 2023 | GEOMAR Helmholtz-Zentrum für Ozeanforschung Kiel | All rights reserved
Questions, comments and suggestions regarding the GEOMAR repository are welcomed
at bibliotheksleitung@geomar.de !