Inter-laboratory study for the certification of trace elements in seawater certified reference materials NASS-7 and CASS-6.

Yang, Lu, Nadeau, Kenny, Meija, Juris, Grinberg, Patricia, Pagliano, Enea, Ardini, Francisco, Grotti, Marco, Schlosser, Christian , Streu, Peter, Achterberg, Eric P. , Sohrin, Yoshiki, Minami, Tomoharu, Zheng, Linjie, Wu, Jingfeng, Chen, Gedun, Ellwood, Michael J., Turetta, Clara, Aguilar-Islas, Ana, Rember, Robert, Sarthou, Géraldine, Tonnard, Manon, Planquette, Hélène, Matousek, Tomáš, Crum, Steven and Mester, Zoltán (2018) Inter-laboratory study for the certification of trace elements in seawater certified reference materials NASS-7 and CASS-6. Analytical and Bioanalytical Chemistry, 410 (18). pp. 4469-4479. DOI 10.1007/s00216-018-1102-y.

[thumbnail of Yang.pdf] Text
Yang.pdf - Published Version
Restricted to Registered users only

Download (888kB) | Contact
[thumbnail of 216_2018_1102_MOESM1_ESM.pdf] Text
216_2018_1102_MOESM1_ESM.pdf - Supplemental Material
Restricted to Registered users only

Download (354kB) | Contact

Supplementary data:

Abstract

Certification of trace metals in seawater certified reference materials (CRMs) NASS-7 and CASS-6 is described. At the National Research Council Canada (NRC), column separation was performed to remove the seawater matrix prior to the determination of Cd, Cr, Cu, Fe, Pb, Mn, Mo, Ni, U, V, and Zn, whereas As was directly measured in 10-fold diluted seawater samples, and B was directly measured in 200-fold diluted seawater samples. High-resolution inductively coupled plasma mass spectrometry (HR-ICPMS) was used for elemental analyses, with double isotope dilution for the accurate determination of B, Cd, Cr, Cu, Fe, Pb, Mo, Ni, U, and Zn in seawater NASS-7 and CASS-6, and standard addition calibration for As, Co, Mn, and V. In addition, all analytes were measured using standard addition calibration with triple quadrupole (QQQ)-ICPMS to provide a second set of data at NRC. Expert laboratories worldwide were invited to contribute data to the certification of trace metals in NASS-7 and CASS-6. Various analytical methods were employed by participants including column separation, co-precipitation, and simple dilution coupled to ICPMS detection or flow injection analysis coupled to chemiluminescence detection, with use of double isotope dilution calibration, matrix matching external calibration, and standard addition calibration. Results presented in this study show that majority of laboratories have demonstrated their measurement capabilities for the accurate determination of trace metals in seawater. As a result of this comparison, certified/reference values and associated uncertainties were assigned for 14 elements in seawater CRMs NASS-7 and CASS-6, suitable for the validation of methods used for seawater analysis.

Document Type: Article
Keywords: Dissolved trace metals, Seawater, Certified reference material, Isotope dilution, HR-ICPMS, Flow injection analysis, Standard addition calibration
Research affiliation: OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-CH Chemical Oceanography
OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-CH Chemical Oceanography > FB2-CH Water column biogeochemistry
Refereed: Yes
Open Access Journal?: No
Publisher: Springer
Date Deposited: 08 May 2018 07:19
Last Modified: 23 Apr 2021 09:32
URI: https://oceanrep.geomar.de/id/eprint/42983

Actions (login required)

View Item View Item