OceanRep
Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic acid, Nitrate plus Nitrite in Seawater.
Altahan, Mahmoud Fatehy , Esposito, Mario and Achterberg, Eric P. (2022) Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic acid, Nitrate plus Nitrite in Seawater. Sensors, 22 . Art.Nr. 3479. DOI 10.3390/s22093479.
Preview |
Text
sensors-22-03479.pdf - Published Version Available under License Creative Commons: Attribution 4.0. Download (2MB) | Preview |
Archive
sensors-22-03479-s001.zip - Supplemental Material Available under License Creative Commons: Attribution 4.0. Download (464kB) |
Abstract
Accurate, on-site determinations of macronutrients (phosphate (PO43−), nitrate (NO3−), and silicic acid (H4SiO4)) in seawater in real time are essential to obtain information on their distribution, flux, and role in marine biogeochemical cycles. The development of robust sensors for long-term on-site analysis of macronutrients in seawater is a great challenge. Here, we present improvements of a commercial automated sensor for nutrients (including PO43−, H4SiO4, and NO2− plus NO3−), suitable for a variety of aquatic environments. The sensor uses the phosphomolybdate blue method for PO43−, the silicomolybdate blue method for H4SiO4 and the Griess reagent method for NO2−, modified with vanadium chloride as reducing agent for the determination of NO3−. Here, we report the optimization of analytical conditions, including reaction time for PO43− analysis, complexation time for H4SiO4 analysis, and analyte to reagent ratio for NO3− analysis. The instrument showed wide linear ranges, from 0.2 to 100 μM PO43−, between 0.2 and 100 μM H4SiO4, from 0.5 to 100 μM NO3−, and between 0.4 and 100 μM NO2−, with detection limits of 0.18 μM, 0.15 μM, 0.45 μM, and 0.35 μM for PO43−, H4SiO4, NO3−, and NO2−, respectively. The analyzer showed good precision with a relative standard deviation of 8.9% for PO43−, 4.8% for H4SiO4, and 7.4% for NO2− plus NO3− during routine analysis of certified reference materials (KANSO, Japan). The analyzer performed well in the field during a 46-day deployment on a pontoon in the Kiel Fjord (located in the southwestern Baltic Sea), with a water supply from a depth of 1 m. The system successfully collected 443, 440, and 409 on-site data points for PO43−, Σ(NO3− + NO2−), and H4SiO4, respectively. Time series data agreed well with data obtained from the analysis of discretely collected samples using standard reference laboratory procedures and showed clear correlations with key hydrographic parameters throughout the deployment period.
Document Type: | Article |
---|---|
Keywords: | Griess reagent, nutrients analysis, Kiel Fjord, posphomolybdenum blue method, silicomolybdenum blue method, vanadium chloride reduction |
Research affiliation: | OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-CH Chemical Oceanography > FB2-CH Water column biogeochemistry OceanRep > GEOMAR > FB2 Marine Biogeochemistry > FB2-CH Chemical Oceanography |
Main POF Topic: | PT6: Marine Life |
Refereed: | Yes |
Open Access Journal?: | Yes |
Publisher: | MDPI |
Related URLs: | |
Date Deposited: | 03 May 2022 12:44 |
Last Modified: | 07 Feb 2024 15:46 |
URI: | https://oceanrep.geomar.de/id/eprint/55905 |
Actions (login required)
View Item |
Copyright 2023 | GEOMAR Helmholtz-Zentrum für Ozeanforschung Kiel | All rights reserved
Questions, comments and suggestions regarding the GEOMAR repository are welcomed
at bibliotheksleitung@geomar.de !